AP Solution HTD 0640 HVAC Tie-Down secures your rooftop unit to the structure. Tie-downs can be installed with the system or retrofitted as needed.
Winds as light as 50-60 mph can dislodge your outdoor unit from its base, causing damage to the unit and your roof. The HTD 0640 protects your unit from damage and prevents costly repairs. The U-Anchor™ 2000 Series Attachments by Anchor Products have proven effective in securing HVAC equipment in harshest conditions caused by earthquakes or hurricanes.
HVAC SYSTEMS SECUREMENT
FEATURES:
» Attaches safely to single-ply, asphalt and coated roofs without damaging the roof using a U-Anchor 2000 Series Attachment.
» The ultimate force resistance of each 2000 series U-Anchor is approximately 2,713 lbs. in tension and 4,339 lbs. in shear.
» The 3/16” stainless steel 7×19 aircraft cable offers a breaking strength of approximately 3700 lbs. (Other wire rope options available upon request.)
» The U-Anchor can be used with all HVAC Equipment.
» All exposed components and hardware are stainless steel, aluminum, or other non-corrosive materials. U-Anchors
ADVANTAGES
» Quick and easy install.
» Stainless steel straps and cables ensure that the metal will not corrode or deteriorate in the harshest of environments.
» The HVAC Tie-Down Securement using the U-Anchors will not void the roof warranty.
The ultimate force resistance of each U-Anchor™ is approximately 3000 lbs. in tension and 4000 lbs. in shear. The 3/16”, 7×19 stainless steel wire rope offers a breaking strength of approximately 3700 lbs. (Other wire rope options available upon request.) The U-Anchor can be used with all HVAC Equipment. All exposed components and hardware are stainless steel, aluminum, or other non-corrosive materials.
Features:
Attaches safely to single-ply, asphalt and coated roofs without damaging the roof using a U-Anchor 2000 Series Attachment
U-Anchors match roofing material type and brand
Install anytime of the year
The force resistance of each U-Anchor is approximately 3000 lbs. in tension and 4000 lbs. in shear
The 3/16”, 7×7 stainless steel wire rope offers a nominal breaking load strength of 3700 lbs. (Other wire rope options available upon request.)
The U-Anchor can be used with all manufacturers HVAC Equipment
Bracket, Straps, and cables are made of stainless steel and will not corrode on the roof
U-Anchor is accepted by all major North American roofing manufacturers allowing warranties to remain in effect
The HVAC Tie-Down Solution consists of stainless steel straps and cables that ensures the metal will not corrode or deteriorate in case of any extreme weather conditions. https://www.anchorp.com/anchor-solutions/hvac/ |